Davey Fire Fighting Pump Placement Beside a Tank on Acreage

November 29, 2026 Off By Willa Drummond

On a rural block, the fire pump next to the water tank is the piece of equipment that turns stored water into something you can use when fire arrives. Where that pump sits, relative to the tank, the house and the driveway, affects how easily it primes, how long it keeps running in heat and smoke, and whether you can reach it safely on a bad day. A well chosen pump in a poor position can still let you down.

Start with the job the pump has to do

Before choosing a spot, work out what the pump will feed. On most acreage it supplies one or more fire hoses, roof or gutter sprinklers, or a combination of both. The distance and height from the pump to the furthest outlet set how much pressure the pump needs to produce. A hose that has to reach the far side of a shed on a slope asks far more of a pump than a sprinkler line running along a flat verandah.

Pump choice and placement are worked out together. Dural Irrigation lists a davey fire fighting pump kit, the 5290HRS, which pairs a 9HP twin impeller pump with a Honda iGX270 petrol engine and includes a mobility kit, thermal sensors and a battery. Twin impeller pumps are generally chosen where higher pressure is needed for long hose runs or uphill delivery. This unit also has a remote start function that sends SMS feedback and warnings to registered users over the Telstra network, and the engine is designed to shut down when the fuel runs out or the oil alert system trips. Ongoing SMS use depends on reception and subscription status, which has a direct bearing on where you put it.

Keep the suction side short and below the water

The single most useful placement rule is to set the pump so its inlet sits below the lowest outlet on the tank. This is called a flooded suction. Water flows into the pump under gravity, so it primes readily and does not have to lift water before it can push it. Engine driven fire pumps can draw water up from below, but suction lift costs performance, makes priming slower and gives air more chances to get into the line.

Keep the suction line as short and straight as you can. A few metres from the tank outlet to the pump inlet is a sensible aim. Use pipe or non-collapsible suction hose at least the same diameter as the pump inlet, and avoid humps in the line where air can collect. Every extra bend, length of hose and reducer adds friction on the side of the pump that handles it worst.

Fit a valve at the tank outlet so the pump can be isolated and removed for servicing without draining the tank. A strainer on the suction side helps keep leaves, sediment and tank debris out of the impellers. Check and clean it as part of routine maintenance, because a blocked strainer starves the pump just when demand is highest.

Set aside water that only the fire pump can reach

Where one tank supplies both the house and the fire pump, a common arrangement is to draw domestic water from an outlet partway up the tank and connect the fire pump to an outlet at or near the base. The household then cannot use the bottom portion, which stays in reserve for firefighting. Many councils and rural fire services set a minimum dedicated firefighting volume for properties in bushfire prone areas, so check your development consent or bushfire assessment for the figure that applies to your block.

Any above-ground pipework and fittings between the tank and the pump should be metal. Plastic fittings and exposed poly pipe can soften or fail in radiant heat, and a melted fitting at the tank outlet can drain the reserve onto the ground. Poly lines are better buried, with metal risers where they come up to the pump or to a hose connection.

Protect the pump from heat and embers

A fire pump needs shelter, but it also needs air. The engine draws air for combustion and cooling and pushes out hot exhaust, so a sealed box is a poor choice. A non-combustible enclosure with good ventilation, or a masonry or steel shield on the side facing the most likely fire approach, gives protection without choking the engine. In much of southern Australia that is often the north-west side, though local terrain and prevailing winds matter more than a general rule.

Clear the area around the pump and tank of mulch, long grass, woodpiles, stored timber and anything else that will burn. Embers collect against walls and in corners, so a pump tucked into a gap between a shed and a garden bed is at higher risk than one on a clear pad.

Think about the route between the house and the pump. You may need to refuel, restart or check it while conditions are poor, and a pump sited across an open paddock facing the fire front is hard to reach. A remote start unit reduces how often you need to walk out to it, but you should still be able to get there along a protected path. Store spare fuel in an approved container away from the pump enclosure, not inside it.

Make the tank usable by fire crews

On acreage, your tank can also be a water source for firefighters. Fire and Rescue NSW runs a program for identifying and signing properties with tanks, pools and dams that firefighters can draw from. Reporting on that work in the Hunter has described how firefighters struggle to find enough water during bushfires and how marked static supplies help.

If crews may use your tank, place the pump and its fittings so they do not block access to the outlet a tanker would connect to. A firm, level standing area for a vehicle close to the tank helps, as does a clear driveway that a truck can turn on. Fire services in each state specify the fitting type and size they need on a tank outlet, so confirm the requirement with your local brigade or rural fire service before fitting one.

Plan the delivery lines and hoses

On the delivery side, the aim is to get water to where it is needed with as little pressure loss as possible. Larger diameter pipe for long runs, fewer fittings and buried lines all help. If the pump feeds roof sprinklers, the pipe to the roof line should be metal where it is exposed, and each zone should be able to run at once without dropping pressure below what the sprinklers need.

Fire hoses should be stored near the pump in a dry, shaded spot, connected or ready to connect, and long enough to reach every side of the house and key outbuildings. Lay the hose out at least once to check the reach rather than relying on a measurement taken from a site plan.

Base, weather and reception

A level concrete pad slightly raised above surrounding ground keeps the pump stable and out of pooling water. It also reduces vibration and makes it easier to keep the area clear. If you have a mobility kit or trolley, the pad still matters, because the pump will spend most of its life parked in one place.

Between fire seasons, the pump sits through sun, rain and dust. A pump cover helps protect the engine and controls. For remote start units, keep the battery charged and check that the exact spot where the pump sits has reliable mobile reception. A position behind a hill or a large steel shed can have far weaker signal than the house, and the remote start and SMS alerts depend on it.

Keep drinking water in mind

If the tank also supplies drinking water, the fire pump connection is part of the household water system. The national enHealth guidance on installing and maintaining household rainwater tanks covers matters such as keeping tanks sealed, managing sediment and maintaining pumps and connections. Keeping the fire pump area tidy, capping unused outlets and avoiding fuel spills near the tank all help protect the water you drink.

Getting the sizing right

Placement decisions feed straight into pump sizing. The suction arrangement, the length and diameter of delivery lines, the height to the furthest outlet and the number of outlets running at once all change the pressure and flow you can expect. Dural Irrigation offers pump sizing and recommendations, with phone advice and technical support. Having your tank size, the planned pump position, the distances and height differences, and the outlets you want to run ready before you call makes that conversation far more useful.

Test it where it sits

Once the pump is in place, run it under load, through the hoses and sprinklers, before each fire season and regularly during it. Check that it primes quickly from the tank, that pressure at the furthest hose is adequate and that the remote start and SMS alerts work from the pump’s actual position. Check fuel, oil and battery each time, top up the tank if the reserve has dropped, and clear any growth that has crept back around the enclosure.

Frequently asked questions

Should the fire pump sit above or below the tank?

Below the tank’s lowest outlet where you can. With a flooded suction, water runs into the pump under gravity, so it primes readily and does not have to lift water before it can deliver it.

How far from the tank should the pump be?

As close as practical. A few metres of straight suction line, at least as wide as the pump inlet, keeps friction and air out of the side of the pump that handles them worst.

Can one tank supply both the house and the fire pump?

Yes, if the house draws from an outlet partway up the tank and the fire pump from one at or near the base, so the bottom portion stays in reserve for firefighting. Check your development consent or bushfire assessment for the minimum volume your block needs.

Does a remote start pump need mobile reception at the pump itself?

Yes. The remote start and SMS alerts work over the mobile network, so test the signal at the exact spot where the pump sits, not at the house. A hill or a large steel shed can weaken it badly.